Services
Dedicated to accurate analysis, quality service and superior performance, Baron
Consulting Co. operates in a custom designed facility that houses state of the
are instrumentation. The following is a comprehensive list of the equipment Baron
Consulting employs to conduct the types of services listed below.
Atomic Absorption
Chromatography
Emission Spectrometers
Infrared, UV/VIS Spectrophotometers
Thermal Analyzers
Miscellaneous
Quality Assurance / Quality Control
- Perkin-Elmer 3030B Atomic Absorption Spectrophotometer with background correction
- Shimadzu 670/67OG Atomic Absorption Spectrometer with Shimadzu ASC 6OF Autosampler
- PerkinElmer Plasma 40 ICP Emission Spectrometer with software
- Dionex Series 4000i Gradient Ion Chromatograph with conductivity and electrochemical
detectors
- Hewlett-Packard HP 1090 Series M Liquid Chromatograph with thermal conductivity, FIU,
and NIP detectors and capillary/packed columns and a gassampling valve
- Hewlett-Packard 5890 Gas Chromatographs with thermal conductivity, FID and N/P detectors
and capillary/packed columns and a gas-sampling valve
- Hewlett-Packard 5890 Series 11 Gas Chromatograph, 0-1, Analytical 4460A Purge & Trap
Sample Concentrator, a MPM-16 Multiple Purging Module Autosampler and MHC-16 Multiple
Heater Controller
- Hewlett-Packard ChemStation Software (DOS series) for multiple instrument use
- Hewlett-Packard 5971C GC/MS, a NBS 75K library search
- Enviroquant software for environmental applications, an 0-1-Analytical 4460A Purge &
Trap Sample Concentrator with a MPM-16 Multiple Purge Module Autosampler and a MHC-16
Multiple Heater Controller
- Hewlett-Packard 5995B GC/MS with ChemStation Software and NBS Spectra Library
- Perkin-Elmer Sigma 1 Gas Chromatograph with electron capture and FID
- Perkin-Elmer 8500 Gas Chromatograph with FID and PID in series
- Tekmar LSC-2 Purge & Trap Sample Concentrator
- Perkin-Elmer LCI-100 Integrator electron capture, 700A Hall Cell and photoionization
detectors, Rainin Rabbit HPLC System with Gilson 231 Autosampler
- Shimadzu GC 8AIE Electron Capture Gas Chromatograph
- Hewlett-Packard 5890GC/5972MS with Autosampler, and 75K library search.
- Applied Research Laboratories M-5 Emission Spectrometer, 1 meter
- Perkin-Elmer Inductively Coupled Plasma 40 Emission Spectrometer with software.
- Perkin-Elmer FT/112 Spectrum BX with appropriate software
- Perkin-Elmer Model 1760-X Research FI'-IR Spectrometer with a FT'-IR M 1700 Microscope
- 1700 Optical Module, on Pentium computer running Win95, Spectrum for Windows, Spectrum
Search and Libraries, QUANT-3 software, and spectra libraries
- Perkin-Elmer 1430 VIR ratio recording Infrared Spectrometer with Perkin-Elmer 3600 Data
Station
- Perkin-Elmer 599B Infrared Spectrometer
- PerkinElmer Lambda 6 UVNis Spectrophotometer, with integration Lab Sphere
- Hach DR/3000 Spectrophotometer
- Perkin-Elmer 2400 CHN Elemental Analyzer with Perkin-Elmer 3600 Data Station
- Perkin-Elmer TGA-2 Thermogravimetric Analyzer
- Perkin-Elmer DSC-4 Differential Scanning Calorimeter
- Perkin-Elmer TMA-2 Thermal Mechanical Analyzer.
- Brinkmann E 576 Potentiometric Titrimeter
- Kyoto AT-310 Potentiometric Titrator
- Coulometrics 5010 Total Organic Carbon (TOC) Analyzer
- Coulometrics 5020 Carbon Dioxide Analyzer
- Coulometrics 5030 Carbon Trioxide Analyzer
- Dohrmann MC-1 (DX-20) TOX Analyzer
- Brinkman 633/1 Karl-Fischer Titrator
- Olympus BH-2/MT-AS 300 Microscope with phase contrast and polarized light capability
- Varian T-60 Nuclear Magnetic Resonance Spectrometer
- PerkinElmer Centrifuge Type E-06
- Dionex SFE-723 Supercritical Fluid Extractor
- Dohrmann (Phoenix 8000) TOC Analyzer
- Mitsubishi TOX 10 Sigma Analyzer
In addition to the instrumentation listed above, there is a wide range of physical
testing and wet chemical equipment.
| Types of Investigations and
Services |
TOP |
Baron Consulting Company provides analytical and quality control
services and performs complex method developments and problem solving investigations for
our clients. Baron also serves clients in a number of other functions including process
and product troubleshooting, investigations of unknowns, formulations as well as routine
analysis and general consulting.
Baron Consulting Company is certified by the State of Connecticut Department of
Health Services (#PH 0440) and The Commonwealth of Massachusetts Department of
Environmental Quality Engineering, and the American Industrial Hygiene Association (AHIA
#6951). Baron Consulting Company is a participating member in the United States
Environmental Protection Agency proficiency testing program (#CT 015). Baron Consulting
Company is prepared to conduct investigations into plastics and polymers, coatings,
pigments, industrial raw materials (including metals and alloys), product improvement and
other materials requiring chemical analysis. Baron Consulting Company has
the capability to perform many methods following ASTM standards or USP/NF procedures.
Baron Consulting Company can aid in
the growing cost of QA/QC. With the instrumentation and expertise available at Baron
Consulting Company off-site Quality Assurance / Quality Control can be achieved
for raw materials or finished products in a cost effective manner for your company.
The laboratory requirements for Good Manufacturing Practices (GMP) will
be satisfied by using your required in-house methods and protocols. Data,
documentation, calibration, and certification reports will be available at all times.
The qualified and experienced chemists at Baron Consulting
Company will also be available for on-site evaluations and modifications of
methods, where appropriate, to facilitate economic and process improvements.
The QA/QC available can include classical wet chemistry, gas
chromatography, liquid chromatography, spectroscopy, thermal analysis, EPA methods, ASTM
standards, or USP/NF protocols.
Top